Product Orientation

2–8

445-0089-01-01

INVERTER Switch

This switch is active in all Display modes: ON, OFF, CONFIGURE.

INVERTER LEDs

The LEDs are continuously updated whenever the Display Mode switch is set to
ON or CONFIGURE.

Switch Position

Description

ENABLE

The inverter is enabled and will run if there is no shorepower.
(

NOTE:

Throughout this manual, the term “shorepower” refers to

AC input power from a utility grid, generator, or other source.)

DISABLE

When the AC power does not meet configuration parameters (i.e. is
“bad”), the inverter is off and will consume minimal power.
When the AC power is good, the inverter is off and will consume
minimal power. The PROsine’s transfer relay is in the “Pass
Through” position. (The transfer relay allows shorepower to pass
through the PROsine to the AC output terminals whenever AC is
connected unless there is an error, or the PROsine is turned Off
with the PROsine ON/OFF/REM switch.)

LED

Description

STANDBY

and

STANDBY
LED Status

INVERTING
LED Status

OFF

OFF

Inverter is not running because it has not been enabled or a
system error has occurred.

OFF

ON

The unit is inverting.

INVERTING

ON

OFF

Invert is enabled, but the unit is not inverting because of an
error or because shorepower is “good.”

INVERT FLASHING

Unit is searching in Load Sense mode.

AC IN

OFF

“Good” shorepower has not been detected.

ON

“Good” shorepower has been detected.

FLASHING

Shorepower line and neutral are reversed or neutral is
disconnected. Have an electrician check the wiring.