SERVICE TECHNICIAN ONLY — read and follow completely.

Ratings

Table 10

GOLD WGO oil water boiler ratings

®

Boiler Model

Number

(9)

I=B=R

Burner

Capacity

GPH

(3)

DOE

Heating

Capacity

MBH

(4) (2)

Net

I=B=R

Ratings

(5)

MBH

(2)

DOE

Seasonal

Efficiency %

Afue

Minimum I=B=R

Chimney

Round

Flue

Outlet

Size In

(7)

Boiler

Water

Content

Gallons

Draft Loss

Thru Boiler

In W.C.

(8)

Rect

In

Round

In

Height

Ft

*WGO-2

0.70

86

75

86.4

8 x 8

6

15

7

11.0

0.010

*WGO-2PLUS

0.95

114

99

85.3

0.010

*WGO-3R

0.80

98

85

86.2

8 x 8

6

15

7

14.9

0.020

*WGO-3

0.95

115

100

85.3

0.020

*WGO-4R

1.00

122

106

86.2

8 x 8

6

15

7

13.4

0.010

*WGO-4

1.20

145

126

85.0

0.010

*WGO-5R

1.20

147

128

86.1

8 x 8

7

15

7

15.9

0.015

*WGO-5

1.45

175

152

85.0

0.015

*WGO-6R

1.40

171

149

86.1

8 x 8

7

15

7

18.4

0.015

*WGO-6

1.75

212

184

85.0

0.015

*WGO-7R

1.60

196

170

86.0

8 x 8

8

15

7

20.8

0.015

*WGO-7

2.00

242

210

85.0

0.015

**WGO-8

2.30

266 (6)

231

-

8 x 12

8

20

7

23.3

0.025

**WGO-9

2.55

295 (6)

257

-

25.8

0.030

*

Substitute “P” for completely assembled packaged boiler without burner (WGO-3 through WGO-6 only).

Substitute “A” for boiler only for use with approved burners as listed with I=B=R.

**

Available only as an “A” unit.

(1)

WGO boiler designed with convertible vertical and horizontal flue outlet.

(2)

MBH refers to thousands of Btu per hour.

(3)

Based on 140,000 Btu/gal.

(4)

Based on standard test procedures prescribed by the United States Department of Energy at combustion condition of 13.5% CO

2

and -0.02" W.C. draft overfire.

(5)

Net I=B=R ratings are based on net installed radiation of sufficient quantity for the requirements of the building and nothing

need be added for normal piping and pick-up. Water ratings are based on a piping and pick-up allowance of 1.15. An additional

allowance should be made for unusual piping and pick-up loads. Consult local Weil-McLain Sales Office.

(6)

I=B=R gross output

(7)

See page 12 for minimum breeching diameter.

(8)

Listed draft losses are for factory-shipped settings.

(9)

Boiler model suffixes: "R" designates a reduced input version. NOTE: A burner nozzle change is required — refer to the burner

instructions or boiler’s rating label for correct selection.

Part number 550-141-826/1211

42

GOLD

WGO

OIL-FIRED NATURAL DRAFT WATER BOILER — SERIES 3 —

Boiler Manual