HOMEOWNER and SERVICE TECHNICIAN — read and follow completely.

Follow instructions below to prevent severe personal

injury, death or substantial property damage:

• To avoid electric shock, disconnect electrical supply to burner

service switch and additional external switches before perform-

ing service.

• To avoid severe burns, allow boiler to cool before performing

service.

• Do not block flow of combustion or ventilation air to boiler.

• Boiler must be connected to a flue with sufficient draft at all times

to assure proper operation.

• Do not use this boiler if any part has been under water. Electrical

and mechanical failures may cause electric shock and fire risks.

Immediately call a qualified service technician to inspect chimney

or vent, boiler and burner. Have the boiler flueways cleaned and

have the following replaced:
• all electrical and mechanical controls
• electrical wiring
• oil burner and controls
• insulation and chamber lining

Tips for water systems —

• Check boiler and system piping for leaks. Continual makeup water

will reduce boiler life. Minerals can build up in sections, reduc-

ing heat transfer and causing cast iron to overheat, resulting in

section failure.

Failure to maintain recommended pH and repair leaks

can cause section iron corrosion, leading to section

failure and leaks. Do not use petroleum-based sealing

or stop-leak compounds in boiler systems. Damage to

system components can result, causing property damage.

• Boiler water pH 7.0 to 8.5 is recommended. For pH conditions

outside 7.0 to 8.5 range or unusually hard water areas (above 7

grains hardness), consult local water treatment company.

• When using antifreeze:

❏ Use antifreeze especially made for hydronic systems. Inhibited

propylene glycol is recommended.

Do not use automotive, ethylene glycol, undiluted or

petroleum-based antifreeze. Severe personal injury, death

or substantial property damage can result.

❏ 50% solution provides protection to about –30°F.

❏ Local codes may require back-flow preventer or actual discon-

nect from city water supply.

❏ Determine quantity according to system water content. Boiler

water content is listed on back cover of Boiler Manual.

❏ Percent of solution will affect sizing of heat distribution units,

circulator and expansion tank.

❏ Follow antifreeze manufacturer’s instructions.

❏ Do not add cold water to hot boiler. Thermal shock can cause

sections to crack.

Please read before proceeding

Homeowner —

• For homeowner or person responsible for

simple start-up and routine maintenance of

the system

• Instructions on page 1 through page 7 must

be followed to assure proper operation of your

boiler. See page 7 for lists common problems

and possible corrections. In addition, it is your

responsibility to:
• Have boiler and burner installed by a quali-

fied installer.

• Have boiler and burner serviced annually

by a qualified service technician.

• Review and understand start-up and rou-

tine maintenance procedures with quali-

fied service technician.

• Perform routine maintenance as described

on page 5.

Service technician —

• For a qualified service technician who has the

necessary equipment to check the boiler and

system performance, and is responsible for

start-up and service of boiler and system.

• All instructions in this manual must be fol-

lowed to assure proper operation of this boiler.

• Annually service boiler and burner to assure

proper operation. See page 29 for service

record.

• Review and explain start-up and routine main-

tenance procedures with homeowner.

Follow instructions below to prevent

severe personal injury, death or sub-

stantial property damage:

• Do not use crankcase drainings or any oil

containing gasoline. See burner manual for

proper fuel oil.

• Do not attempt to start burner when excess

oil has accumulated in combustion chamber,

when unit is full of vapor, or when combustion

chamber is very hot.

• Do not start burner unless collector hood, flue

cap, jacket cap, breeching and burner mount-

ing door are secured in place.

• Never burn garbage or paper in the boiler.

Never leave combustible material around

boiler.

• DO NOT TAMPER WITH UNIT OR CON-

TROLS. Always follow specific instructions

when starting up boiler or performing routine

maintenance or service.