SERVICE TECHNICIAN ONLY — read and follow completely.

Connect water piping

(continued)

Figure 13

Piping with CIRCULATORS

Figure 14

Piping with ZONE VALVES

Piping for systems requiring
temperatures below 140°F

In most systems, this type of piping is not required. If
system water temperature requirements are less than
140°F, such as radiant panels or converted gravity sys-
tems, use piping as shown in Figure 13 or Figure 14. If
system piping is plastic without an oxygen barrier, a
heat exchanger must be used.

Legend

1

Isolation valve

2

Flow control valve

3

Circulator

4

System temperature
gauge

5

Zone valve

6

Drain valve

7

System temperature
valves
Adjust valves so that:
- the temperature at
gauge 8 is at least 140°F
- the temperature at
gauge 9 is at least 160°F

8

Blend temperature
gauge

9

Boiler temperature
gauge

Part number 550-141-826/1211

21

GOLD

WGO

OIL-FIRED NATURAL DRAFT WATER BOILER — SERIES 3 —