Install burner — all boilers, Boiler manual – Weil-McLain 550-141-826/1201 User Manual
Page 15
SERVICE TECHNICIAN ONLY — read and follow completely.
Figure 6
Water boiler controls
Install burner
(also refer to instructions packed with
burner)
Use only burners specified for use on
Weil-McLain GOLD oil boilers. DO
NOT use burners specified for use on
Weil-McLain Model 68 boilers. Contact
individual burner manufacturers for
proper burner selections.
Relief
valve
Water
pressure-temperature
gauge
Limit control / low water cut-off
Drain valve
Circulator
For P-WGO and A-WGO boiler:
1. Secure universal mounting flange and gasket to burner mounting door.
Use three bolts provided.
2. Secure burner on flange with three bolts.
3. Position burner so end of air tube is level to 1½° tilt downward. Open
door to verify burner position. End of air tube should be flush to ¼"
recessed from inside wall of burner door refractory. Check for secure
placement of insulation on target wall, chamber floor and burner
mounting door. Securely close door with nut.
Install burner — all boilers
Part number 550-141-826/1211
15
GOLD
WGO
OIL-FIRED NATURAL DRAFT WATER BOILER — SERIES 3 —
Boiler Manual