beautypg.com

Connect water piping, Boiler manual – Weil-McLain 550-141-826/1201 User Manual

Page 20

background image

SERVICE TECHNICIAN ONLY — read and follow completely.

Zone 2

Zone 1

1

2

5

5

1

2

1

3

1

Piping MULTIPLE ZONES

1. Follow instructions on page 18

and page 19 to

install piping near boiler.

2. See Figure 11

or Figure 12 to complete installation

3. Zoning with circulators:

a. Size each circulator to individual circuit re-

quirements.

b. Remove circulator (when furnished as standard

equipment).

c. Install balancing valves to adjust flow to distrib-

ute heat to all zones.

d. Separate relay is required for each circulator.

4. Zoning with zone valves:

a. Install balancing valves to adjust flow to distrib-

ute heat to all zones.

b. Separate transformer is required to power zone

valves. Refer to “Weil-McLain Zone Valve Wir-
ing Guide” for details.

Connect water piping

(continued)

Figure 12

Multiple zoning with ZONE VALVES

Zone 2

Zone 1

1

4

5

5

1

1

1

Figure 11

Multiple zoning with CIRCULATORS

Legend

1

Isolation valve

2

Flow control valve

3

Circulator

4

Zone valve

5

Drain valve

Part number 550-141-826/1211

20

GOLD

WGO

OIL-FIRED NATURAL DRAFT WATER BOILER — SERIES 3 —

Boiler Manual