Rs-232 host parameters, Rs-232 host parameters -6 – Wasp Bar Code Wasp Duraline WLS 8400 FZ User Manual
Page 94
WLS 8400 Product Reference Guide
6-6
RS-232 Host Parameters
Various RS-232 host types are set up with their own parameter default settings. Selecting
the host type sets the parameter defaults as listed in
Table 6-2. Terminal Specific RS-232
Parameter
Standard
RS-232
(Default)
ICL
Wincor-
Nixdorf
Mode A
Wincor-
Nixdorf
Mode B
Olivetti
Omron
OPOS/
JPOS
Fujitsu
Transmit
Code ID
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Data
Transmission
Format
Data as is
Data/
Suffix
Data/
Suffix
Data/
Suffix
Prefix/
Data/
Suffix
Data/
Suffix
Data/
Suffix
Data/
Suffix
Suffix
CR/LF
(7013)
CR (1013) CR (1013) CR (1013) ETX
(1002)
CR (1013) CR (1013) CR (1013)
Baud Rate
9600
9600
9600
9600
9600
9600
9600
9600
Parity
None
Even
Odd
Odd
Even
None
Odd
None
Hardware
Hand-
shaking
None
RTS/CTS
Option 3
RTS/CTS
Option 3
RTS/CTS
Option 3
None
None
RTS/CTS
Option 3
None
Software
Hand-
shaking
None
None
None
None
Ack/Nak
None
None
None
Serial
Response
Time-out
2 Sec.
9.9 Sec.
30.0 Sec.
30.0 Sec.
9.9 Sec.
9.9 Sec.
30.0 Sec.
2 Sec.
Stop Bit
Select
One
One
One
One
One
One
One
One
ASCII
Format
8-Bit
8-Bit
8-Bit
8-Bit
7-Bit
8-Bit
8-Bit
8-Bit
Beep On
Disable
Disable
Disable
Disable
Disable
Disable
Disable
Disable
RTS Line
State
Low
High
Low
Low = No
data to
send
Low
High
Low = No
data to
send
Low
Prefix
None
None
None
None
STX
(1003)
None
None
None