Appendix a specifications, Autoloader main unit – Tandberg Data Autoloader Tandberg LTO2 User Manual
Page 77
- 61 -
Appendix A Specifications
Autoloader Main Unit
Maximum data storage capacity
200GB
10
*1
(400GB
*2
10
*1
)
*1 9 for Tandberg LTO2 Autoloader w/BCR
*3
*2 2:1 compressed
*3 with Bar Code Reader
Number of cartridges
Max. 10
*1
SCSI Interface
Ultra160 LVD
Dimensions(including
filter) 223(W)696(D)178(H) mm
*4
[8.8(w)
27.4(D)
7.0(H) in.]
*4 A vacant space of 5U is required when
R a c k m o u n t k i t o p t i o n a l mounting this Autoloader into a rack.
Weight
Less than 18kg (39.7lbs.)
Maximum data transfer rate
35MB/s (native)
70MB/s (at 2:1 compressed)
Line voltage
AC100-127/200-240V (auto voltage select)
Line
frequency
50/60Hz
Power consumption
1.3 - 0.5A
Environmental
conditions
[Operating]
Temperature
10ºC - 35ºC (50ºF - 95ºF)
Relative humidity
20% - 80%RH (non-condensing)
Wet bulb temperature
26ºC maximum (79ºF)
[Non-operating
*5
]
Temperature
–40ºC - 60ºC (-40ºF - 140ºF)
Relative humidity
10% - 90%RH (non-condensing)
Wet bulb temperature
26ºC maximum (79ºF)
[Storage
*6
]
Temperature
16ºC - 32ºC (61ºF - 90ºF)
Relative humidity
20% - 80%RH (non-condensing)
Wet bulb temperature
26ºC maximum (79ºF)
*5 without cartridge tapes
*6 with cartridge tapes (non-operational cartridge)