- 55 -

Phenomenon Recovery

Procedure

Cartridge Operation

Cartridge is entwined in the
transporter.

Execute cleaning of the Roller.See”Section 5.1.2”
If the phenomenon has a relapse,contact your nearest Customer Support

Center.

Transporter does not
load/unload the cartridge.

Execute cleaning of the Roller.See”Section 5.1.2”
If the phenomenon has a relapse,contact your nearest Customer Support

Center.

The cartridge could not be taken
out from the drive.

Execute cleaning of the Roller.See”Section 5.1.2”
If the phenomenon has a relapse,contact your nearest Customer Support

Center.

Connections

Host does not detect
Autoloader.

Check whether the terminating connector is mounted to the Autoloader

and whether the cables are properly connected.

Check whether the Autoloader is recognized by the operating system.

Backup software application of
the host does not detect
Autoloader.

When the backup software detects the drive but does not detect the

Autoloader, check whether the Autoloader module or the changer option
accompanies the backup software. Most software packages require an
Autoloader "robotic" and an additional module for communications.

When the backup software detects the Autoloader but does not detect the

drive, check whether the correct backup software driver has been
installed.

Changed SCSI ID of the drive is
not recognized by the host
computer.

Check whether different ID numbers have been assigned to the SCSI

devices on the same bus.

Restart the host.

After connection to the
Autoloader, the response speed
slows down, or the system
stops.

Check that there are no conflicts of the SCSI ID among all the devices

connected to the host.

There is no need to put the SCSI ID in a specific order on the backup

software.