7 start and shutdown of the system, Important – Tandberg Data Autoloader Tandberg LTO2 User Manual
Page 29
- 13 -
2.7 Start and Shutdown of the System
When the SCSI ID settings have been completed, switch on the power of the server/workstation
and the other devices and start the system.
To start the system, switch ON the power in the order of the Autoloader (along with the
peripherals connected to the server/workstation) and then the server/workstation.
Important
If the data cartridge is loaded into the tape drive before starting the system, the
reading/writing of data recorded on the data cartridge may not be performed
properly.
To shut down the system, switch OFF the power in the order of the server/workstation and then the
Autoloader (along with the peripherals connected to the server/workstation).
Important
Before shutting down the system, check that a data cartridge is not loaded in the
tape drive. If the system is shut down while the data cartridge is still loaded in
the tape drive, the next time the system is started, the reading/writing of data
recorded on the data cartridge may not be performed properly or this could
cause damage to the data cartridge or this device.
Do not shut down or restart the system while this device is operating. Check
that this device is stopped before closing down or restarting the system.
Important
If an error message is shown as "Unreadable Media" on the PC console’s
screen without front panel LED lighting solid red during the following
operations, Inventory, Erase, Backup, Restore and etc., please retry the same
operation. Also if the cartridge remains in the drive, please eject the cartridge
from the drive by manual operation (refer “3.5 Operation of the Panel Keys”)
before retrying the operation.