Tandberg Data Autoloader Tandberg LTO2 User Manual
Page 39

- 23 -
Operation Examples
The operation procedure and LCD indications are described below when loading the cartridge
housed in slot 7 into the drive.
Operation 1
Switch ON the power and wait for the completion of the power-on test.
Display:
"READY" and "DRV empty" are alternately displayed.
Operation 2
Press the ENTER key.
Display:
STATUS
Operation 3
Press the arrow key and select the "LOAD" command.
Display:
LOAD
Operation 4
Press the ENTER key and define the command.
Display:
Load Drv?
Operation 5
Press the ENTER key and define the command.
Display:
Frm Slt 1?
Operation 6
Press the arrow key and select "Slt 7".
Display:
Frm Slt 7?
Operation 7
Press the ENTER key and execute the command.
Display: Complete (when the command ends normally.)
Err. xxxxxx (when an error occurs. xxxxxx is the error code.)