3.4.2 Removal from and Insertion to the Fixed Slots
Operation 1
Remove the cartridges that are housed in the fixed slots (i.e., slot 8 to
10). (The cartridges will move to slot 5 to 7 within the magazine at this
time.)
Operation 2
Reload a magazine into the main unit that has vacant slots for slot 5 to
7.
Operation 3
Lock the front door and wait for "READY" to be displayed.
Operation 4
Press the "ENTER" key.
Display:
STATUS
Operation 5
Press the "arrow" key and select the EJECT command.
Display:
EJECT
Operation 6
Press the "ENTER" key and define the command.
Display:
Eject Drv?
Operation 7
Press the "arrow" key and select "Eject Sl
ot?" .
Display:
Eject Sl
ot?
Operation 8
Press the "ENTER" key and execute the command.
Display: Complete (when the command ends normally.)
Err. xxxxxx (when an error occurs. xxxxxx is the error code.)
Operation 9
When required, remove the magazine and remove the cartridges of slot
5 to 7 which have been moved.
Tip
•Ejecting by command is valid only when slot numbers 5 to 7 among the
magazine slots are all vacant slots.
•When ejecting by command is executed, all cartridges housed in slot numbers
8 to 10 within the fixed slots are moved to the magazine.