beautypg.com

A5.6 ram clear – Toshiba TEC CB-426-T3-QQ User Manual

Page 112

background image

Appendix 5 System Mode

104

A5.6

RAM Clear

Notes:

When pressing the FEED and
RESTART keys at the same time
in RAM Clear or “NO RAM
CLEAR”, the message returns to
“<4> RAM CLEAR”.

After RAM clear, the following items
are still stored: X/Y direction fine
adjustment value, total label
distance covered, sensor adjustment
value and data in the flash memory.

The RAM Clear menu contains the following:

Maintenance Counter clear.

Parameter clear.

Print Step clear.

While pressing the FEED and PAUSE keys at the same time,
turn on the printer. Hold both keys until the “<1> DIAG.” message
appears. Then press the FEED key three times.

RAM clear functions are ready to be performed. Press the PAUSE key.

Press the PAUSE key not to perform a RAM clear.
The message returns to “<4> RAM CLEAR”.
Press the PAUSE key. “NO RAM CLEAR” appears again. Press
the FEED key.

Clearing the Maintenance Counter

The Maintenance Counter can be cleared by pressing the PAUSE key.

The Maintenance Counter is cleared.
The printer must be turned off to exit this mode.

Clearing the Parameter

When “<4> RAM CLEAR” is shown, press the PAUSE key.
“NO RAM CLEAR” appears again. Press the FEED key twice.

The parameters can be cleared by pressing the PAUSE key.

The parameters are cleared.
The printer must be turned off to exit this mode.

<1>DIAG. V1.0

<4>RAM CLEAR

NO RAM CLEAR

Note:

See A5.7.7 for further information
about the initial values after clearing
the Maintenance Counter.

MAINTE CNT CLEAR

COMPLETE

Note:

See A5.7.8 for further information
about the initial values after clearing
the parameters.

NO RAM CLEAR

PARAMETER CLEAR

COMPLETE