Appendix 5 System Mode

99

Specifying the Control Code Selection Method

Select the Control Code methods: “AUTO” (automatic selection),
or “ESC, LF, NUL” or “{, ,}” or (manual selections).
After selecting the method, press the PAUSE key.

Select one of the following pulse motor speeds: AUTO or 104.
If selecting “AUTO”, the pulse motor cycle varies depending on
the operating temperature. If “104” is selected, the pulse motor
cycle is fixed at 104%.
After selecting the pulse motor speed, press the PAUSE key.

Specifying the Euro Code

Select one of the following Euro codes: FFH, FEH to B0H, B0H
to 21H or 20H.
After selecting the Euro code, press the PAUSE key.
The message returns to “PRINTER PARA”.

Adjusting the Pulse Motor Speed

After “PRINTER PARA” appears, press the FEED key.

To make a fine adjustment of the pulse motor speed, press the
PAUSE key.

The acceptable values are -60 to +60. As the value becomes lower,
the motor speed becomes faster.
After adjusting the pulse motor speed, press the PAUSE key.
The message returns to “<2> PARAMETER SET”.

Note:

See A5.7.4 for further information
about the pulse motor speed.

CODE AUTO

PULSE MOTOR AUTO

EURO CODE B0

Note:

Use the FEED or RESTART key
to select a desired value.

PRINTER PARA

PM ADJUST

PM ADJ. +0