5-9

5-15. RS-232C Control Method

Signals are connected to the RS-232C connector in a

straight format as shown in Table 5-15-1 RS-232C

connection signals. This is because a crossing connec-

tion is provided inside the unit. Communication condi-

tions are set to meet the conditions given in Table 5-15-2.

Table 5-15-3 shows the command list of RS-232C.

When transmitting the command, be always sure to keep

100 ms interval between each command. Moreover, the

process time is required for a while when turning the

power ON/OFF and/or selecting the input mode. So in

such cases, also be always sure to keep enough intervals

between the commands.

Table 5-15-1 RS-232C connection signals

Table 5-15-2 RS-232C communication conditions

Pin No.

2

3

4

5

6

7

8

Item

Communication system

Communication type

Signal name

RXD

TXD

DTR

S. G

DSR

RTS

CTS

Signal content

Receive data

Transmit data

Data terminal ready

Signal ground

Data set ready

Transmission request

Transmission enable

I/O

I

O

O

I

I

O

I

Conditions

Transmission speed 9600 baud, No parity, Data length 8 bit, Stop bit: 1 bit

STX (1 byte) + CMD (3 byte) + ETX (1 byte) = 1 block
STX is 02h, ETX is 03h, CMD is command string (Uppercase character)