Section 1 Introduction

1-12

Dry Weight:

145 lbs (66 kg) Refrigerator only, no controller or bottle configuration

160 lbs (73 kg) Includes refrigerator, controller, top cover, center section, tub,
pump tube, distributor shaft extension, distributor arm and nut, and discharge
tube for the 24 plastic bottle configuration.

Dry Weight With:

24 plastic bottles, rack, hold down, no caps

175 lbs(79 kg)

24 glass bottles, rack, expander ring, no caps

195 lbs(88 kg)

12 plastic bottles, rack, hold down, no caps

175 lbs(79 kg)

8 plastic bottles, rack, adaptor, no caps

170 lbs(77 kg)

8 glass bottles, rack, adaptor, no caps

180 lbs(82 kg)

2 plastic bottles, rack, no caps

175 lbs(79 kg)

2 glass bottles, rack, no caps

165 lbs(75 kg)

1-9.4 l plastic bottle and cap, no distributor arm or nut165 lbs(75 kg)
1-9.4 l glass bottle and cap, no distributor arm or nut 170 lbs(77 kg)
1-15.0 l plastic bottle and cap, no distributor arm or nut165 lbs(75
kg)
1-20.5 l plastic bottle and cap, no distributor arm or nut165 lbs(75
kg)
1-18.5 l glass bottle and cap, no distributor arm or nut 170 lbs(77 kg)

Filled Bottle Weight:

24 plastic bottles

101 lbs(46 kg)

24 glass bottles

104 lbs(48 kg)

12 plastic bottles

89 lbs (41 kg)

12 glass bottles

95 lbs (43 kg)

8 plastic bottles

84 lbs (38 kg)

8 glass bottles

90 lbs (41 kg)

4 plastic bottles

98 lbs (45 kg)

4 glass bottles

104 lbs(48 kg)

1 plastic bottle

90 lbs (41 kg)

1 glass bottle

94 lbs (43 kg)

Average Thermal
Resistance Factor:

R-16

The average R-value for a complete FR refrigerator not running

Recovery time

5 minutes

Recovery time is the time for the internal air temperature to return to 39°F (4°C) after the door has been opened for
one minute. The empty refrigerator is running and set at 39°F (4°C). The door is opened at least 4 minutes after the
compressor has turned on. Ambient air temperature is 75°F (24°C).

Thermostat

Set point range: 32° to 46°F (0° to 8°C)
Set point accuracy: ±1.8°F (±1°C) at 39°F (4°C)

[With an ambient air temperature of 75°F (24°C)]

Temperature Ranges

Operational: -20° to 120°F (-29° to 49°C)
Storage: 0° to 140°F (-18° to 60°C)

Environment

Rain and spray resistant, but not watertight. Do not install in locations where the
refrigerator’s lower compartment could become submerged.

Electrical

Power Requirements: 120 Volts, 60 Hz

230 Volts, 50 Hz

(optional)

Running current:

3.5 amp

1.75 amp

Starting current:

17 amp

8.5 amp

Stalled Compressor current:21 amp

10.5 amp

(maximum)

Table 1-3 Technical Specifications for the 6712FR Refrigerated Sampler (Continued)