beautypg.com

Send diagnostic command (1dh) (continued) – Quantum Instruments DLT 7000 User Manual

Page 266

background image

SCSI Commands

5-162

Quantum DLT 7000 Tape System

SEND DIAGNOSTIC Command (1Dh) (continued)

NOTE

Because of data generation and verification, this test only streams
the tape for short periods of time. If Block Count is set very high,
the test can take many minutes or even many hours to complete.

If the specified diagnostic test passes, a GOOD status is returned. Otherwise, a
CHECK CONDITION is generated and the Sense Data contains information
about the failure.

Table 5–78 Sense Keys Used for SEND DIAGNOSTIC

Sense Key

Description

3h

Medium Error. A positioning error has occurred in which the returned position does
not match the expected position. Additional Sense Code for possible additional
information.

4h

Hardware Error. The Additional Sense Code and any Additional Sense Code Qualifier
provide more specific information.

5h

ILLEGAL REQUEST. Illegal bit settings in the SEND DIAGOSTIC command.

Eh

Miscompare. A compare error occurred during a READ operation.

Additional Sense Codes and Additional Sense Code Qualifiers that apply to
SEND DIAGNOSTIC self-test results are described in the table below.

Table 5–79 ASC / ASCQ for SEND DIAGNOSTIC

ASC

ASCQ

Description

15h

2h

A positioning error has occurred in which the returned position does
not match the expected position.

40h

80h

Level 1 ROM Test Failed.

40h

81h

Level 1 RAM Test Failed.

40h

82h

Level 1 Test Failed. Bad Drive Status.

40h

83h

Level 1 Test Failed. Loader Reset Failed.