Table 5–21 Log Parameters for Read / Write Error LOG SENSE Page Field Descriptions

(continued)

Field Name

Description

TMC
(continued)

The criteria for comparison are:

Code - Basis of Comparison

00b - Every update of the cumulative value

01b - Cumulative value equal to threshold value

10b - Cumulative value not equal to threshold value

11b - Cumulative value greater than threshold value

LP

List Parameter. This bit is 0 since the parameter codes are treated as data counters.

Parameter
Length

This field specifies the number of bytes of the parameter value.

Parameter
Value