Quantum Instruments DLT 7000 User Manual
Page 220

SCSI Commands
5-116
Quantum DLT 7000 Tape System
MODE SENSE (6) / (10) Command (1Ah / 5Ah) (continued)
5.10.3.4 Data Compression Page (0Fh)
The Data Compression page specifies parameters for the control of data
compression.
Bit
Byte
7
6
5
4
3
2
1
0
0
PS (0)
Rsv’d
Page Code (0Fh)
1
Page Length (0E)
2
DCE
DCC
Reserved
3
DDE (0)
RED (0)
Reserved
4 - 7
(MSB)
Compression Algorithm
(LSB)
8 - 11
(MSB)
Decompression Algorithm
(LSB)
12 - 15
Reserved
Figure 5–56 Data Compression Page - Data Format