LOG SENSE Command (4Dh) (continued)
Bit
Byte
7
6
5
4
3
2
1
0
0 -1
(MSB)
Parameter Code
(LSB)
2
DU
DS
TSD
ETC
TMC
Rsv’d
LP
3
Parameter Length
4 - 11
(MSB)
Parameter Value
(LSB)
NOTE: Byte 2 is also referred to the Parameter Control Byte.
Figure 5–19 Log Parameters Format for Read /Write Error LOG SENSE Page
Table 5–21 Log Parameters for Read /Write Error LOG SENSE Page Field Descriptions
Field Name
Description
Parameter
Code
Parameter Codes supported for the READ/WRITE error counter pages are as follows:
Parameter Code - Descriptions
00h
- Errors corrected with substantial delays
01h
- Errors corrected with possible delays
02h
- Total rewrites or rereads
03h
- Total errors corrected
04h
- Total times correction algorithm processed
05h
- Total bytes processed
06h
- Total uncorrected errors