3.4.1
Setting IP and Control Preferences
An IP address is required for the SNMP manager to address the 10/100M. The factory default setting is
192.168.1.220. The IP address can be configured manually or automatically as a DHCP client.
3.4.1.1
Setting IP Parameters Manually
To manually configure the IP address and control parameters, select 3 from the Management Options
screen. The IP and Control Preferences screen will appear.
IP and Control Preferences Screen
iConverter, Serial Agent
1: Set IP
192.168.1.220
2: Set Subnet Mask
255.255.255.0
3: Set Gateway
192.168.1.1
4: Chassis Number
1
5: Chassis Name (also sysName)
10/100M
6: Enable/Disable TELNET
Enabled
7: Enable/Disable FTP
Disabled
8: Enable/Disable Soft Switch Reload
Disabled
9: TELNET Password
*****
10: FTP Password
11: Serial Password
Enter Choice, Management Options Screen(0), (H)elp, E(x)it >
To configure the IP address of the 10/100M, select 1 at the IP and Control Preferences screen, and press
<ENTER>. Backspace over the existing value, type the new value (in x.x.x.x format), and press <ENTER>.
To configure the subnet mask of the 10/100M, select 2 at the IP and Control Preferences screen, and press
<ENTER>. Backspace over the existing value, type the new value (in x.x.x.x format), and press <ENTER>.
To configure the gateway of the 10/100M, select 3 at the IP and Control Preferences screen, and press
<ENTER>. Backspace over the existing value, type the new value (in x.x.x.x format), and press <ENTER>.
To save the new values, select 0 and press <ENTER> to return to the Management Options screen, then
select 6 and press <ENTER> to Save Preference Changes.
3.4.1.2
Setting IP Parameters as DHCP Client
To configure the IP automatically as a DHCP client, select 9 from the Management Options screen. The
Other Networking Features screen will appear.