Parameter address map, System realtime message, System exclusive message – Roland SP-606 User Manual
Page 94
94
MIDI Implementation
■
System Realtime Message
●
Timing Clock
Status
F8H
*
This message is transmitted only if Tx MIDI Sync is ON.
●
Start
Status
FAH
*
This message is transmitted only if Tx MIDI Sync is ON or during EXT SEQ
SAMPLING.
●
Continue
Status
FBH
*
This message is transmitted only if Tx MIDI Sync is ON or during EXT SEQ
SAMPLING.
●
Stop
Status
FCH
*
This message is transmitted only if Tx MIDI Sync is ON or during EXT SEQ
SAMPLING.
●
Active Sensing
Status
FEH
■
System Exclusive Message
●
Universal Non-realtime System Exclusive
Messages
❍
Identity Reply
Status
Data byte
Status
F0H
7EH, 10H, 06H, 02H, 41H,F7H
6EH, 01H, 00H, 00H,
00H, 02H, 00H, 00H
Byte
Explanation
F0H
Exclusive status
7EH
ID number (universal non-realtime message)
10H
Device ID
06H 02H
Identity Reply
41H
ID number (Roland)
6EH 01H
Device family code
00H 00H
Device family number code
00H 02H 00H 00H
software revision level
F7H
EOX (End Of Exclusive)
●
Data set 1 (DT1)
Status
Data byte
Status
F0H
41H, 10H, 00H, 6EH, 12H,F7H
aaH, bbH, ccH, ddH, eeH,...
ffH, sum
Byte
Explanation
F0H
Exclusive status
41H
ID number (Roland)
10H
Device ID
00H 6EH
Model ID (SP-606)
12H
Command ID (DT1)
aaH
Address MSB
bbH
Address
ccH
Address
ddH
Address LSB
eeH
Data: the actual data to be sent. Multiple bytes of data are
transmitted in order starting from the address.
: :
ffH
Data
sum
Checksum
F7H
EOX (End Of Exclusive)
3. Parameter address map
■
Addresses Transmitted and Received When
Switching to EXT Mode
The following address is transmitted and received when switching to EXT mode.
Address
Description
Data (Value)
00 00 00 00
EXT Control mode
0 (OFF),
1 (ON/PART SELECT),
2 (ON/MUTE),
3 (ON/SOLE),
4 (ON/SEQ TRIGGER),
5 (ON/NOTE TRIGGER)
SP-606_e.book 94 ページ 2004年6月21日 月曜日 午前10時8分