5 v power source, 5 v power source -3, R to the – National Instruments Network Device DAQ S User Manual
Page 27

Chapter 3
I/O Connector
© National Instruments Corporation
3-3
+5 V Power Source
(NI 6124 Only)
The +5 V pins on the I/O connector supply +5 V power. You
can use these pins, referenced to D GND, to power external circuitry.
Power rating (most devices): +4.65 to +5.25 VDC at 1 A.
To find your device’s power rating, refer to the specifications document for
your device.
Caution
Never connect these +5 V power pins to analog or digital ground or to any other
voltage source on the S Series device or any other device. Doing so can damage the device
and the computer. NI is not liable for damage resulting from such a connection.
PFI <0..5>/P0.<0..5>
D GND
Input
Programmable Function Interface or Static Digital
Input Channels 0 to 5—Each of these terminals can be
individually configured as a PFI terminal or a digital input
terminal.
As an input, each PFI terminal can be used to supply an
external source for AI or AO timing signals or
counter/timer inputs.
Note: PFI <0..5>/P0.<0..5> are isolated from earth
ground and chassis ground.
PFI <6..9>/P1.<0..3>
D GND
Output
Programmable Function Interface or Static Digital
Output Channels 6 to 9—Each of these terminals can be
individually configured as a PFI terminal or a digital
output terminal.
As a PFI output, you can route many different internal AI
or AO timing signals to each PFI terminal. You also can
route the counter/timer outputs to each PFI terminal.
Note: PFI <6..9>/P1.<0..3> are isolated from earth
ground and chassis ground.
D GND
—
—
Digital Ground—D GND supplies the reference
for input PFI <0..5>/P0.<0..5> and output PFI <6..9>/
P1.<0..3>.
Note: D GND is isolated from earth ground and chassis
ground.
NC
—
—
No Connect—Do not connect signals to these terminals.
Table 3-2. NI 6154 I/O Connector Signal Descriptions (Continued)
I/O Connector Pin
Reference
Direction
Signal Description