Dsm ds1x84 termination module (tm), Equipping rules, Dsm ds1x84 termination module (tm) 3-111 – Nortel Networks OPTera Metro 3500 User Manual
Page 339: Equipping rules 3-111
Hardware feature descriptions 3-111
Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004
Figure 3-38
DSM OAM (Hardware Release 6) with cover on
EX1438p
DSM DS1x84 termination module (TM)
(NTN313AA, AC)
The DSM DS1x84 termination module (DSM DS1x84 TM) has been
developed for use in the DS1 service module (DSM). The DSM DS1x84 TM
supports 84 DS1 facilities.
For each DSM DS1x84 TM, you need one OC-3 interface installed in the
OPTera Metro 3500 shelf.
Note: You are recommended to use the DS1 right-angle cable assembly
with the DSM shelf.
Equipping rules
When you order the DS1 service module (NTN407AA), DS1x84TM circuit
packs (NTN313AA) and DSM Shelf (NTN407MA) are included.
When you order the DS1 service module (NTN407AC), DS1x84TM circuit
packs (NTN313AC) and DSM Shelf (NTN407MA) are included.
When you order the DS1 service module (NTN407MA), you must order the
DS1x84TM circuit packs (NTN313AA or NTN313AC) for slots 1 and 2
separately.
The DS1x84TM circuit pack is an intermediate reach optical interface,
compliant with OC-3x4 optical specifications.