2-104 Operation, administration, and maintenance (OAM) features

OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

See

Table 2-22

for a list of performance monitoring parameter definitions. For

a list of DS3 performance monitoring parameters supported on the DS3 circuit
packs, see

Table 2-23

. For a list of DS1 performance monitoring parameters

supported on the DS1 and DS3VTx12 circuit packs, see

Table 2-24

.

Table 2-22
Performance monitoring parameter definitions

Parameters

Definitions

Section

CV-S

Coding violations,
section

• SONET: Count of BIP-8 errors (B1) byte

ES-S

Errored seconds,
section

• SONET: Count of one second intervals with

BIP-8 errors (B1) >=1 or LOF >=1 or LOS >=1

SES-S

Severely errored
seconds, section

• SONET: Count of one second intervals with

BIP=8 errors (B1) >=K (where K is 155 for OC-3,
616 for OC-12, 2392 for OC-48, 8854 for
OC-192) or SEF >=1 or LOS >=1

SEFS-S

Severely errored frame
seconds, section

• SONET: Count of one second intervals with any

LOF >=1

Line

CV-L

Coding violations, line

• SONET: Count of BIP-8 errors (B2 byte)

• DS1 / DS3x3 / DS3x12 / DS3x12e: Count of

BPV + EXZ BPVs which are part of the B3ZS
code are not counted, receive only

CV-LFE

Coding violations, line,
far-end

• SONET: Count of FEBE-L (Bits 2-8 of Z2 byte of

STS-1 No. 3)

ES-L

Errored seconds, line

• SONET: Count of one second intervals with

BIP-8 errors (B2) >=1 or AIS-L >=1

• DS1 / DS3: Count of one second intervals with

(BPV + EXZ) >=1 or LOS >=1, receive only

ES-LFE

Errored seconds, line,
far-end

• SONET: Count of one second intervals with

FEBE-L >=1 or RDI-L >=1

• DS1-ESF: Count of one second PRM intervals

with LV=1 in the PRM, receive and transmit

SES-L

Severely errored
seconds, line

• SONET: Count of one second intervals with

BIP-8 errors (B2) >=K (where K is 154 for OC-3,
615 for OC-12, 2459 for OC48, 9835for
OC-192) or AIS-L >=1

• DS3: Count of one second intervals with (BPV +

EXZ) >=44 or LOS >=1, receive only

• DS1: Count of one second intervals with (BPV +

EXZ) >=1544 or LOS >=1, receive only

This manual is related to the following products: