Operation, administration, and maintenance (OAM) features 2-157
Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004
Synchronization-status messages are carried in bits 5 through 8 of the S1 byte
in the SONET line overhead and in the extended superframe (ESF) datalink of
the external DS1 signal from a BITS or a tributary. As the timing is passed
from one network element to the next, each network element sends SSMs. If
the quality of the timing changes, the SSMs inform the next network element
of the change. See
.
Table 2-33
Synchronization status messages and quality levels
Description
Quality
level
SONET S1 byte
(bit 5 to bit 8)
Designation
ESF datalink
code byte
Stratum 1—Traceable
1
0001
ST1 (PRS)
000010
Synchronized—
Traceability unknown
2
0000
STU
000100
Stratum 2—Traceable
3
0111
ST2
000110
Stratum 3—Traceable
4
1010
ST3
001000
SONET minimum
clock—Traceable
5
1100
SMC
010001
Stratum 4—Traceable
(see Note 1)
6
n/a
ST4
010100
Do not use for
synchronization
8
1111
DUS
011000
Reserved for network
synchronization use
(holdover)
7
1110
RES
100000
Note 1: The ST4 message is carried in the ESF datalink of an external DS1 timing
signal, not in the SONET overhead.
Note 2: Any unsupported synchronization status message S1 or DS1 ESF datalink
is byte-mapped to a DUS designation.