Nortel Networks OPTera Metro 3500 User Manual
Page 201
Operation, administration, and maintenance (OAM) features 2-163
Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004
Figure 2-53
Test access-monitor state
EX1397t
The monitoring configurations supported include:
•
Single Facility Access Digroup, Monitor Equipment side (Single FAD,
MONE) see
•
Single Facility Access Digroup, Monitor Facility side (Single FAD,
MONF) see
•
Dual Facility Access Digroup, Monitor Equipment and Facility sides
(Dual FAD, MONEF) see
“equipment side” and “facility side”
shows the direction(s) of the connection under test.
Single FAD, MONE and Single FAD MONF
In a single FAD environment, only one direction of the signal can be monitored
at a time.
In the case of Single FAD, MONE, the monitored connection is from the
equipment side input to the facility side output, see A transmission path as
shown in
In the case of Single FAD, MONF, the monitored connection is from the
facility side input to the equipment side output, see B transmission path as
shown in
Input
Output
Test
Unit
TAP Out