Nortel Networks Remote Gateway 50 User Manual
Page 224
Page 224 of 258
Dialing Plan configuration
553-3001-207 Standard 2.00 January 2006
To configure the NRS (H.323 Gatekeeper):
•
Create H.323 endpoints: “MO”, “BO”.
•
Create Numbering Plan entries:
— Choose type “UDP-LOC”.
— Add “504” for endpoint “BO”.
— Add “501” for endpoint “MO”.
To configure the SRG:
•
Create route and destination code to main office.
•
In the main office screen:
— Set the type of number to ESN LOC.
— The VoIP trunk access code field is empty.
— Set the main office Access Code Length to 1.
Note: You can also include the LOC as the dial out when you configure
the route for the VoIP line pool. This allows users to dial fewer numbers.
For example, if 501 is configured as the dialout, and 6 is the destination
code, the user could dial 6+
identifies the route (VoIP trunks) and drops the 6, it adds the LOC in
front of the DN and dials
IP Phones, the BUID is
code length, in this circumstance, is set to 1.
•
Dialing plan:
— Set Type to UDP.
— Set LOC to 504.
•
Set the BUID on the IP Phones to
For more information on configuring the main office and NRS, refer to
Branch Office: Installation and Configuration (553-3001-214) and IP Peer
Networking: Installation and Configuration (553-3001-213). For more
information on configuring the SRG, refer to SRG50 Configuration Guide.