beautypg.com

Nortel Networks Remote Gateway 50 User Manual

Page 105

background image

Bandwidth Management

Page 105 of 258

Main Office Configuration for Survivable Remote Gateway 50

Configuration Guide

No branch office HLOC is shared with the main office,
but can be shared with another branch office

In Figure 26, the first half of the call is shown (originator side of the call). In
Figure 27 on

page 106

, the second half of the call is shown (destination side

of the call).

Figure 26
Call flow for Scenario 1 - call to remote branch office (originator side)

1

The branch office user dials 6-444-3456. The system transmits 444-3456
to the NRS. The NRS checks its provisioning, and determines that all
calls are to be sent to the main office; it directs the call to the main office.

2

The branch office sends the call to 444-3456 to the main office.

3

The main office determines that this is to another main office. The
system transmits 444-3456 to the NRS. The NRS checks its
provisioning, and determines that this call goes to main office B.