beautypg.com

Navman 11 User Manual

Page 43

background image

43

MN002000A © 2004 Navman NZ Ltd. All rights reserved. Proprietary information and specifications subject to change without notice.

Message ID: 1317
Rate: As required - maximum rate 1 Hz
Message Length: 8 words

Word No.

Name

Type

Units

Range

1-4

Message header

5

Header checksum

6

Sequence number (Note 1)

I

0 to 32 767

7

Power management on duty cycle (Note 2)

I

s

0 = off

1 to 4 = on

8

Data checksum

Note 1: The sequence number is a count that indicates whether the data in a particular binary message has been updated or

changed since the last message input.

Note 2: In power management mode, the RF power may be switched off to reduce power consumption. The digital circuitry may be

gated off and the processor idled when not needed. This field gives the measurement engine permission to turn off the RF for the

minimum off time in seconds.

Table 3-37 Message 1317 (power management control)

3.5.2.15 Message 1317 (power management

control).

This message controls the use of power

management in the receiver. The contents of

the ‘power management control’ message are

described in Table 3-37.

Note: Message 1317 is primarily used to input key

parameters from GPS systems without non-volatile

storage. This is why the format of output message

1117 is exactly the same. In other words, the output

message is used to capture data while the input

message is used to restore data.