beautypg.com

Maximum power cabling distance (approximate), Rpi connector overview, Rpi connector board – Nortel Networks Companion MICS-XC User Manual

Page 31: Rpi connector overview 25

background image

Installation / 25

P0881594 Issue 01

MICS-XC Norstar-Companion Installer Guide

Maximum power cabling distance (approximate)

Depending on the size of cable you are using, you should
remember the maximum cabling distances allowed between
the RPI and the Base Station.

RPI Connector Overview

The following illustration shows where the input and output
connectors are located on the RPI connector board.

RPI connector board

Wire size

Single-pair

Double-pair

0.6 mm (22 AWG)

450 m (1,500 ft.)

900 m (3,000 ft.)

0.5 mm (24 AWG)

300 m (1,000 ft.)

600 m (2,000 ft.)

When using two power pairs, ensure they are
connected with the same polarity.

OBIX1 OBIX2 OBIX3 OBIX4

OBIX9

OBIX10 OBIX11 OBIX12

OBIX5 OBIX6 OBIX7 OBIX8

OBIX13

OBIX14 OBIX15 OBIX16

IBIX1

IBIX3

IBIX2

IBIX4

p0881594.book Page 25 Tuesday, August 25, 1998 3:59 PM