beautypg.com

Event messages, Event messages 100 – Nortel Networks Companion MICS-XC User Manual

Page 106

background image

100 / Troubleshooting

MICS-XC Norstar-Companion Installer Guide

P0881594 Issue 01

Event messages

Event message display

Cause

(U.S. only) Unable to activate all registered
portables. The system ran out of portable credits.
One event is generated per portable that failed to
activate. The repetition of the corresponding alarm
code 59 indicates how many additional credits must
be purchased.

The Base Station (on port 0103 in this case) cannot
successfully receive the data image.

Both radios belonging to the Base Station are
disabled. This may occur if the flash EEPROM is
faulty. Two events are raised: one for the B1
channel radio (as in this case) and another for the
B2 channel radio. A corresponding alarm code 53
occurs.

The Base Station (on port 0103 in this case) cannot
be written to during data transfer.

Both radios belonging to the Base Station are
disabled. The Base Station’s flash EEPROM is
faulty. Two events are raised: one for the B1
channel radio (as in this case) and another for the
B2 channel radio. A corresponding alarm code 53
occurs.

The Base Station (on port 0103 in this case) cannot
be synchronized with the other Base Stations in the
system.

Both radios belonging to the Base Station are
disabled. The Base Station hardware is faulty. Two
events are raised: one for the B1 channel radio (as
in this case) and another for the B2 channel radio.
A corresponding alarm code 53 occurs.

A B2 channel radio (radio 2 on port 0103 in this
case) cannot be synchronized with other radios
because of system overload.

Evt:275-3546

S8

Evt:301-1031

S5

Evt:302-1031

S5

Evt:303-1031

5

Evt:304-1032

p0881594.book Page 100 Tuesday, August 25, 1998 3:59 PM