Rebuild Settings
Beeper – Right-click on the Controller
icon and select Beeper from the
popup menu. A checkmark means the beeper is enabled.
Figure 80. Rebuild Settings in Information View.
Right-click on the Controller
icon and look into Information View. Check the
respective boxes to enable these features:
Enable Hot Spare Disk – Enables a spare drive not assigned to the array to 
automatically replace a failed drive in the array. You must also enable Auto 
Rebuild for this feature to be effective. 
Enable Auto Rebuild – Enables automatic rebuilding of a fault-tolerant (RAID 1, 
0+1 and 5) array when it goes Critical. 
Enable Hot Swap Disk – Allows you to replace a faulty disk drive without 
shutting down the system. This feature works with an externally replaceable disk 
drive enclosure such as the Promise SuperSwap. 
Rebuild Setting – Allocates system resources between rebuilding the array and 
responding to read/write commands from the computer system. 
A High setting assigns most of the system resources to rebuilding. Rebuilding 
goes faster, restoring redundancy sooner but read/write requests are handled 
slower. 
A Low setting assigns most of the system resources to handling read/write 
requests. Read/write requests are handled at nearly normal speed while the 