Controller cache, Disk parameters, Rebuild setting – Promise Technology FastTrak SX Series Version 4.4 User Manual
Page 63

Chapter 5: RAID Monitoring and Maintenance
59
Controller Cache
Allows you to toggle between two write modes for the FastTrak's cache:
Write Through – Data is written to the cache and hard drive at the same time. 
This arrangement is safer. Check the box to select it 
Write Back – Data is written to the cache first and to the hard drive later. This 
arrangement increases performance at the risk of data loss if the power fails. 
Uncheck the box to select it. 
Disk Parameters
Check the respective boxes to enable these features:
Enable Write Cache – Speeds hard disk performance by writing data to the 
cache to increase performance. Note that you can lose data if a power failure 
occurs. 
SMART Check – SMART, an acronym for Self-Monitoring Analysis and 
Reporting Technology, is a feature of the disk drive software. It monitors the 
internal performance of the drive and reports to the PC when it finds a potential 
failure. SMART warns you of a developing drive failure so you can replace the 
drive before it actually fails. 
Rebuild Setting
Check the respective boxes to enable these features:
Enable Hot Spare Disk – Enables a spare drive not assigned to the array to 
automatically replace a failed drive in the array. You must also enable Auto 
Rebuild for this feature to be effective. 
Enable Auto Rebuild – Enables automatic rebuilding of a fault-tolerant (RAID 1, 
0+1 and 5) array when it goes Critical. 
Enable Hot Swap Disk – Allows you to replace a faulty disk drive without 
shutting down the system. This feature works with an externally replaceable disk 
drive enclosure such as the Promise SuperSwap. 
Rebuild Setting – Allocates system resources between rebuilding the array and 
responding to read/write commands from the computer system. 
A High setting assigns most of the system resources to rebuilding. Rebuilding 
goes faster, restoring redundancy sooner but read/write requests are handled 
slower. 
A Low setting assigns most of the system resources to handling read/write 
requests. Read/write requests are handled at nearly normal speed while the 
rebuild takes longer. 
See Rebuild an Array later in this chapter for more information on the rebuilding 
process. 