1 decode zones - se 1200hp, lr and alr, 1 decode zones – se 1200hp, lr and alr – Psion Teklogix Hand-Held Computer 7530 G2 User Manual
Page 270
Chapter 7: Specifications
Decode Zones – SE 1200HP, LR AND ALR
242
Psion Teklogix 7530 G2 Hand-Held Computer User Manual
7.6.2.1
Decode Zones – SE 1200HP, LR AND ALR
Symbologies
UPC/EAN, Code 128, UCC/EAN
128, RSS, Code 39, Code 93, I 2 of
5, Discrete 2 of 5, Codabar, MSI.
PDF417, Micro PDF,
UPC/EAN, Code 39, Inter-
leaved 2 of 5, Code 128, Coda-
bar, MSI Plessey, RSS and
Composite codes.
Programmable
Parameters
Laser On Time, Aim Duration,
Symbology types/lengths, Data
formatting.
Laser On Time, Aim Duration,
Power Mode, Trigger Mode,
Bidirectional Redundancy,
Symbology types/lengths, Data
formatting, Pattern Controls.
Ambient Light:
Artificial: 450 ft. candles
(4844 Lux).
Sunlight: 4000 ft. candles
(43,056 Lux).
Artificial: 450 ft. candles
(4844 Lux).
Sunlight: 8000 ft. candles
(86112 Lux).
Bar Code
Read Distance
High
Performance
Long Range
Advanced
Long Range
Min
Max
Min
Max
Min
Max
5 mil 3.0" 4.5"
7.5 mil 3.0" 8.5"
10 mil 2.5" 12.5" 13.0" 17.5"
15 mil 2.5" 18.5" 8.5" 33.5" 20.0" 50.0"
20 mil 2.5" 20.5" 9.5" 38.5" 30.0" 60.0"
40 mil 3.0" 29.5" 9.5" 79.5" 30.0" 98.0"
55 mil 3.5" 35.5" 9.5" 89.5" 27.0"
115.0
"
Parameter
SE 1200ALR