177

Chapter 5: Configuration

Decoded (Intermec ISCP)

Reading Range

Determines the reading distance from which a bar code can be successfully scanned.
The default setting Extended, allows for increased reading distance.

Check Digit Verification

Uses the specified algorithm of the option you've chosen to ensure the integrity of
the symbol data before transmitting. If the data does not contain that algorithm, the
data is not transmitted. The available options are: Disabled, or French CIP.

Note: French CIP (French pharmaceutical) is only used with bar codes contain-

ing 7 characters.

Minimum Length

Minimum lengths for the bar code can be set from 0 to 255. The length of a code
refers to the number of characters (i.e., human readable characters), including
check digit(s).

Field Size/Chars

Refer to page 148 for details.

5.11.4.5 EAN 13

Enabled

Set this parameter to on to enable “EAN 13”.

ISBN Conversion

When this parameter (International Standard Book Number) is enabled, the first 3
characters (‘978’) are ignored and the checksum (0.9, ‘X’) is calculated on the
remaining characters.

Transmit Check Digit

If the check digit is to be transmitted with the data, this parameter must be enabled.

Prefix/Suffix

See “Prefix/Suffix” beginning on page 151.