Cellular radio address, Polling, Auto radio address – Psion Teklogix Hand-Held Computer 7530 G2 User Manual
Page 167: Manual radio address, Table 5.3 polling parameters sync delay
Psion Teklogix 7530 G2 Hand-Held Computer User Manual
139
Chapter 5: Configuration
Protocol Tab
Cellular Radio Address
Auto Radio Address
If Auto radio address is enabled, the 7530 G2 requests an automatically assigned
radio address. Manual radio address is displayed in grey text indicating that it
cannot be accessed.
Manual Radio Address
The value entered in the Manual Radio Address parameter is used to identify
the 7530 G2 over the radio link. A unique value from 1 to 3840 must be assigned for
each unit.
Note: This parameter is set to ‘0’ (an out-of-range value) by default to block
radio communication when the unit is initially powered up. This prevents
several new hand-helds from attempting to communicate with the same
default terminal number at initial power up. Once the default value is
changed, it cannot be set back to ‘0’.
Polling
The default values for the Polling parameters are dependent on the value assigned to
the Modulation / Baud Rate parameter in the Radio tab.
Table 5.3 Polling Parameters
Sync Delay
Warning:
This parameter should not be changed from its factory setting
without a clear understanding of radio protocol timing.
The “Sync Delay” parameter specifies the delay between the base station
transmission and the first response window, measured in milliseconds. The value
assigned to this parameter must be compatible with other hand-helds and base
stations in the system. The allowable range for this parameter is between 1 and 40.
Modulation / Baud Rate
Sync Delay
Window Delay
Poll Timeout
4 Level / 19200
17
20
20
4 Level / 9600
17
23
25
2 Level / 9600
17
19
22
2 Level / 4800
25
23
37