Subnetwork health and status messages – Paradyne COMSPHERE 3615 User Manual
Page 99

COMSPHERE DualFlow Data Service Units
C-8
December 1996
3615-A2-GB20-20
Table C-5
Subnetwork Health and Status Messages
Message
Condition
Devic
TDM/Flex only: Device Failure. One of the following major alarms is in effect:
Configuration Corrupt
Device Test Failure
DialBU
Dial mode. Indicates that the DBM is active.
DialCN
Dial Connect. Indicates that the DBM is in Standby mode.
DialTn
Dial Tone Test failure.
Disab
Indicates that the DSU or DBM is disabled.
DTR
DTE alarm. Data Terminal Ready lead is Off.
ExtLd
External lead alarm A or B.
Facil
DDS facility alarm. Indicates a network facility alarm.
NoResp
The active poll list member did not respond. Probable cause: a facility problem, a
remote DSU problem, or an incorrect poll list.
Normal
Active poll list member does not report an alarm or its status.
RPower
Redundant power supply alarm.
Stndby
DBM is in Dial Standby.
Stream
Streaming terminal.
SubSpd
Subnormal operating speed.
Test
Test mode. It could be a DSU or DBM test.
Thresh
Threshold is exceeded.
TribTm
Tributary time-out. Tributary is not answering polls.
Trunc
Subtree truncation. More information is being received than can be returned in the poll.
You must access each tributary for its messages.