Model 3616 dsu jumper straps – Paradyne COMSPHERE 3615 User Manual
Page 36
![background image](/manuals/178957/36/background.png)
COMSPHERE DualFlow Data Service Units
3-4
December 1996
3615-A2-GB20-20
Table 3-2
Model 3616 DSU Jumper Straps
Strap
Designation
State of
Jumper Strap
Function
J12
Left
V.35 Test Mode Indication:
Left — Enables V.35 Test Mode Indication (Pins 1 and 2).
This is the factory default.
Right — Disables V.35 Test Mode Indication (Pins 2 and 3).
J13
Left
EIA-232-D Test Mode Indication:
Left — Enables EIA-232-D Test Mode Indication (Pins 1 and 2).
This is the factory default.
Right — Disables EIA-232-D Test Mode Indication (Pins 2 and 3).
J20
Left
Alarm Monitoring (used with the –48 Vdc Central Office Power Unit):
Left — Disables the – 48 Vdc alarm monitoring function
(Pins 1 and 2).
This is the factory default.
Right — Enables the – 48 Vdc alarm monitoring function
(Pins 2 and 3); the NMS adapter cable is being used for alarm
monitoring.
J21
Right
Alarm Monitoring (used with the –48 Vdc Central Office Power Unit):
Left — Enables control of alarm monitoring via the NMS adapter
cable (Pins 1 and 2); the NMS adapter cable is being used for alarm
monitoring.
Right — Disables control of alarm monitoring via the NMS adapter
cable (Pins 2 and 3); a standard EIA-232 cable or the NMS adapter
cable is being used for the diagnostic channel.
This is the factory
default.