Diagnostic dbm configuration options – Paradyne COMSPHERE 3615 User Manual
Page 81
COMSPHERE DualFlow Data Service Units
5-16
December 1996
3615-A2-GB20-20
Table 5-5
Diagnostic DBM Configuration Options
Diag Type: Disr
Next NonD Disr None Prev
Diagnostic Type. Defines the diagnostic interaction between the control and tributary DBMs in Backup mode. It must be
set consistently for all Dualflow DBMs on the same circuit.
NonD
—
Nondisruptive Diagnostics. An in-band secondary channel transport is derived to carry diagnostics data
between the control and the tributary DBMs.
Disr
—
Disruptive Diagnostics. The same (primary) channel that carries user-transmitted data between the
control and the tributary DBMs also carries diagnostic data. This mode should be selected for
compatibility with earlier releases that use session-disruptive diagnostics.
None
—
No diagnostic communications with remote devices; only local diagnostics are allowed.
2nd Ch(bps): 400
Next 100 400 800 1200 1600 Prev
In-band Secondary Channel Diagnostic Transport Speed (in bps). Determines the DBM’s port speed when NonD
(nondisruptive diagnostics) is selected and there is no excess bandwidth available for in-band secondary channel
transport operation. (This configuration option only appears when DiagType = NonD.)
The selection entered here allocates DBM port bandwidth to the in-band secondary channel transport. For example, both
the DBM port speed and the backup line speed are 9.6 kbps, and the Diagnostic Type entered is NonD and the In-band
Secondary Channel Diagnostic Transport Speed entered is 400. The resulting DBM port speed is 9.2 kbps. (Refer to the
following list for valid diagnostic speeds.)
If the DBM Rate(Kbps) is equal to
Port Speed:
Valid diagnostic speeds are:
1.2
100, 400
2.0
100, 400
2.4
100, 400, 800
4.0
100, 400, 800
4.8
100, 400, 800, 1200, 1600
7.2
100, 400, 800, 1200
8.4
100, 400, 1600
9.6
100, 400, 800, 1200, 1600
12.0
100, 400, 800, 1200
14.4
100, 400, 800, 1200, 1600
16.8
100, 400, 800, 1200
18.0
100, 400, 1200
19.2
100, 400, 800, 1200, 1600
28.8
100, 400, 800
32
100, 400, 800, 1200
38.4
100, 400, 800, 1200, 1600
48
100, 400, 800, 1200, 1600
56
100, 400, 800, 1200