beautypg.com

Dsu configuration options – Paradyne COMSPHERE 3615 User Manual

Page 71

background image

COMSPHERE DualFlow Data Service Units

5-6

December 1996

3615-A2-GB20-20

Table 5-1

DSU Configuration Options

Rate(Kbps): 56
Next 64CC 64L 56 38.4 19.2 9.6 4.8 2.4 Prev

DSU Rate. Data rate (in kbps) on the digital circuit. Must be set to match the speed of the DDS circuit. Both the control
and tributary DSUs must be set to the same value.

64CC

64 kbps Clear Channel (on a 72 kbps circuit) with 3600 Series DSUs at both ends of the circuit.

64L

64 kbps LADS operation.

TxClkSource: DDS
Next Int RXC Ext DDS Prev

Transmit Clock Source. Specifies the transmit timing source for the DSU.

Int

Internal clock source. Timing is taken from the DSU.

RXC

Receive clock source. The DSU generates its transmit timing from the receive data signal. This choice is
provided for LADS configurations. It differs from the DDS selection during tests.

Ext

External clock source. The DSU is timed by the external Transmit Timing lead.

DDS

DDS Network. This source is used when the DSU is connected to a DDS network and the network
provides the timing.

19.2 PowrLvl: + 6
Next + 6 0 –10 Prev

19.2 kbps Power Level. Selects the appropriate power level, in dBm, for operation at 19.2 kbps. This configuration option
only appears when

Rate(Kbps) is set to 19.2.

+ 6

For DDS network service.

0

For alternate DDS service.

–10

For LADS operation.

64KScramblng: Off
Next On Off Prev

64 kbps Scrambling. Controls the data scrambler used with 64 kbps Clear Channel operation. Data scrambling
suppresses the possible simulation of network control codes by application data. This configuration option must be the
same at both the local and remote DSUs. This configuration option only appears when

Rate(Kbps) is set to 64CC.

On

Enables data scrambling.

Off

Disables data scrambling.

64KLatchLpbk: On
Next On Off Prev

64 kbps Latching Loopback. Controls the DSU’s response to the network latching loopback sequence on 64

kbps Clear

Channel operation. This configuration option only appears when Rate(Kbps) is set to 64CC.

On

DSU responds to the network latching loopback command. ON is required for compliance with AT&T
Technical Reference 62310 – 1987.

Off

DSU ignores the network latching loopback command.

V.54 Lpbk: Disab
Next Enab Disab Prev

V.54 Loopback. Enables CCITT V.54 Loopback operation. This configuration option is supported for point-to-point
configurations.

Enab

This configuration option should be enabled if the remote DTE generates V.54 loopback sequences or if
the DualFlow DSU is communicating with a non-AT&T DSU that supports V.54

signaling.

Disab

This configuration option should not be enabled if the remote DTE does not support V.54 loopback
sequences or other DSUs do not support V.54 signaling.

This manual is related to the following products: