System Administration

PN: 1725-36097-001_L.doc

53

Replace an MCU

When the system has more than one MCU, each MCU contains a

complete set of configuration information for the entire system. This

includes handset registration information, function definitions, and

frequency sequence selection.
This Configuration Sharing feature allows a failed MCU in a multi-

unit installation to be replaced without having to register the handsets

again.
To replace a failed MCU, first clear the configuration information on

the replacement MCU, then replace the failed MCU.

Clear configuration on replacement MCU

1. Remove power from the replacement MCU. There should be no

IPC cables connected to the IPC ports.

2. Slide the mode switch on the replacement MCU to the

ADMIN

position.

3. Apply power.
4. Press the

STEP

button until the

STATUS

LEDs light

2

,

3

, and

4

of the

replacement MCU.

5. Press the

DEL/ENTER

button.

6. Remove power from the unit.
7. Slide the mode switch to the

NORMAL

position.

Connect the replacement MCU

1. Remove the failed MCU from the IPC chain
2. Connect the replacement MCU in the position vacated by the

failed MCU.

3. Reconnect the IPC cables for the chain. Double-check that the

IN

and

OUT

ports are correctly connected.

4. Apply power to the MCU.