Replace an MCU
When the system has more than one MCU, each MCU contains a
complete set of configuration information for the entire system. This
includes handset registration information, function definitions, and
frequency sequence selection.
This Configuration Sharing feature allows a failed MCU in a multi-
unit installation to be replaced without having to register the handsets
again.
To replace a failed MCU, first clear the configuration information on
the replacement MCU, then replace the failed MCU.
Clear configuration on replacement MCU
1. Remove power from the replacement MCU. There should be no
IPC cables connected to the IPC ports.
2. Slide the mode switch on the replacement MCU to the
ADMIN
position.
3. Apply power.
4. Press the
STEP
button until the
STATUS
LEDs light
2
,
3
, and
4
of the
replacement MCU.
5. Press the
DEL/ENTER
button.
6. Remove power from the unit.
7. Slide the mode switch to the
NORMAL
position.
Connect the replacement MCU
1. Remove the failed MCU from the IPC chain
2. Connect the replacement MCU in the position vacated by the
failed MCU.
3. Reconnect the IPC cables for the chain. Double-check that the
IN
and
OUT
ports are correctly connected.
4. Apply power to the MCU.
- SpectraLink SCE408 SpectraLink SCT416 SpectraLink 1725-36097-001 SpectraLink SCA516 SpectraLink SCK416 SpectraLink SCA408 SpectraLink SCJ408 SpectraLink SCI416 SpectraLink SCN416 SpectraLink SCO416 SpectraLink SCJ416 SpectraLink SCO408 SpectraLink SCS416 SpectraLink SCI408 SpectraLink RCC400 SpectraLink SCK408 SpectraLink SCL408 SpectraLink RCU201 SpectraLink SCA416 SpectraLink SCL416 SpectraLink MOG400 SpectraLink SCM416 SpectraLink SCC408 SpectraLink SCC416 SpectraLink SCD416 SpectraLink SCF416 SpectraLink SCN408 SpectraLink SCE416 SpectraLink SCF4089 SpectraLink SCX416 SpectraLink SCD408