Run cable for system, Run cables to base station locations, Wire specifications – Polycom SpectraLink SCM408 User Manual
Page 17
PN: 1725-36097-001_L.doc
17
Run Cable for System
Run Cables to Base Station Locations
The Base Station locations should be designated on the building floor
plans provided to the Polycom field service engineer. Base Stations
can be mounted easily on raised or acoustical ceiling tiles, or on the
wall. Avoid locating Base Stations in high or hard-to-reach places, as
this will hinder maintenance, testing and/or repositioning.
Wire specifications
The customer’s wire contractor is responsible for adhering to all
local codes for wiring.
Polycom recommends UL-listed wire that conforms to the following
specifications for AWG, distance, and number of power pairs
required for this installation.
Power
Pairs
Max Cable Feet
22 AWG
Max Cable Feet
24 AWG
Max Cable Feet
26 AWG
1
1,100
750
470
2
2,200
1,500
940
3
2,200
2,200
1,400
One additional pair is required for data.
Attenuation must not exceed 6.8 dB/1,000 feet at 772KHz.
Wire that is already installed (spare house cable) can be used when it
is available. House cable will usually run from the MDF in the
telephone equipment room to intermediate distribution frames (IDFs)
spread throughout the facility. Install new wire from the closest IDF
to the Base Station. Be sure no bridge taps, multiples, or “Y”
connections are created or present.
4
- SpectraLink SCE408 SpectraLink SCT416 SpectraLink 1725-36097-001 SpectraLink SCA516 SpectraLink SCK416 SpectraLink SCA408 SpectraLink SCJ408 SpectraLink SCI416 SpectraLink SCN416 SpectraLink SCO416 SpectraLink SCJ416 SpectraLink SCO408 SpectraLink SCS416 SpectraLink SCI408 SpectraLink RCC400 SpectraLink SCK408 SpectraLink SCL408 SpectraLink RCU201 SpectraLink SCA416 SpectraLink SCL416 SpectraLink MOG400 SpectraLink SCM416 SpectraLink SCC408 SpectraLink SCC416 SpectraLink SCD416 SpectraLink SCF416 SpectraLink SCN408 SpectraLink SCE416 SpectraLink SCF4089 SpectraLink SCX416 SpectraLink SCD408