SpectraLink 6100 MCU: Installation and Operation: SpectraLink 6000 System

PN: 1725-36097-001_L.doc

36

STATUS

LEDs

1

,

2

, and

4

must be lit.

LINE

LEDs

1

through

8

(indicating an unconfigured MCU) should also be lit.
If any other combination of

LINE

LEDs is lit, then a switch type has

already been selected. Go to step 5 to pick the desired switch type.

5. Press the

DEL/ENTER

button to select the correct switch interface

type. With each press of the

DEL/ENTER

button, a different series of

LINE

LEDs will be lit. Continue to press

DEL/ENTER

until the correct

LINE

LEDs are lit. Use the following list to select the desired switch

interface.

Switch Interface

Line LEDs

MCU Type

Notes

Analog

1

SCA5xx

The SCA will only support Analog.

Comdial

3

SCD5xx

DEFINITY – Two-wire

1, 4

SCD5xx

DEFINITY – Four-wire

1, 5

SCF5xx

Four-wire Interface.

Executone

2, 5

SCB5xx

The SCB will only support Executone.

Fujitsu

2, 4

SCD5xx

Inter-Tel

2, 3, 4

SCD5xx

Meridian

1, 2

SCN5xx

Merlin Legend

1, 3

SCF5xx

Four-wire Interface.

Mitel

1, 2, 3

SCX5xx

The SCX will only support Mitel.

NEC

1, 2, 4

SCD5xx

Norstar

2

SCN5xx

M7310, two line display

Norstar

1, 6

SCN5xx

M7310, one line display

Panasonic

5

SCP5xx

The SCX will only support Panasonic.

Siemens / Rolm

4

SCD5xx

Toshiba

2, 3

SCD5xx

Unconfigured

1 through 8

6. Move the mode switch back to

NORMAL

.

7. The MCU will cycle through diagnostic testing. When the system

is ready for use, the

ERROR

LED should be off, and the LED for the

MCU Number (

1

to

4

) will be lit. This should take less than two

minutes.
If the LED for the MCU ID does not light, or if an MCU ID is

duplicated, there is most likely a problem with the IPC cabling. If

the system displays an error refer to Chapter 8, section

Troubleshoot Error Codes.