beautypg.com

Prepare demarc blocks, Multiple power pairs – Polycom SpectraLink SCM408 User Manual

Page 20

background image

SpectraLink 6100 MCU: Installation and Operation: SpectraLink 6000 System

PN: 1725-36097-001_L.doc

20

Prepare Demarc Blocks

The MCU connects to the existing telephone system using RJ-21

connections. An MCU is designed to operate with a specific interface

to the telephone system: two-wire digital or analog, or four-wire

digital. The number of demarcation blocks required for the system

depends on the number and type of MCUs installed.

Interface Type

MCU

Part Number

Wire

Pairs

# Blocks

Analog POTS

SCA-5XX

1

1

Universal Digital Interface (Norstar, Meridian, Comdial, Fujitsu,
Inter-Tel, DEFINITY 2-wire, NEC, Rolm, Toshiba)

SCU-5XX

1

1

Merlin Legend and DEFINITY 4-wire

SCF-5XX

2

2

Mitel (DNIC)

SCX-5XX

1

1

Panasonic (Universal 2-wire Auxiliary Digital)

SCP-5XX

1

1

Executone (Universal 4-wire Auxiliary Digital)

SCB-5XX

2

2

If the wiring between the SpectraLink 6100 MCU and the telephone
system leaves the building, consult your telephone system manual
for instructions on providing adequate lightning and other over-
current protection. All MCUs (except the analog interface SCA-5XX)
are intended only for connection to the isolated side of an on-
premises telephone switch. The interfaces are intended to connect
to digital telephone switch ports that provide signals of 5Vp-p (max)
AC component, and some telephone switches provide a 48 V DC
offset.

Based on the number and type of interfaces in the system, determine

the number of 25-pair cables required to connect line ports and Base

Stations to the demarcation blocks.
The diagrams which follow provide an overview of the connections.

Multiple power pairs

Some sites may prefer to wire Base Stations to a separate demarc

block in order to split out power pairs.