Run Listen Verify Diagnostic

The Listen Verify diagnostic is used to determine if Base Stations are

performing correctly. See SpectraLink 6300 MCU: Operator’s Console for

details. When the test is run, each each Base Station stops transmitting

for a short time and listens for other Base Stations. The system checks

signal strength levels between Base Stations to ensure that no Base

Station is installed too close to another. If Base Stations are too close,

one Base Station will be disabled (“locked out”) and an alarm will be

activated, unless the Base Station in question has been designated as

an “isolated” Base Station.
Base Stations with diagnostic listen values of less than -40 dbm are

close to being locked out. If the Base Station is only a few dbm away

from locking out, it should be repositioned to get a lower signal

strength to avoid the lockout.
The Listen Verify test can be run manually or the system can

automatically run it at the same time each day. See SpectraLink 6300

MCU: Operator’s Console for detailed information on how to manually

or automatically run the Listen Verify diagnostic, and how to

interpret results.