Prepare power for shelves, Run cables to base station locations, Wire specifications – Polycom SpectraLink RCO400 User Manual

Page 26

background image

SpectraLink 6300 MCU: Facility Preparation

PN: 1725-36122-001_N.doc

26

Prepare Power for Shelves

The SpectraLink 6300 MCU requires a -48V DC power source. The -

48V connection is comprised of three wires: -48, +48 (neutral), and

ground.
Polycom recommends that a licensed electrician install the -48V

power source. It must be installed according to current National

Electrical Code (NEC) or National Fire Protection Code standards, in

accordance with all local and municipal electrical code

recommendations.
Use of 14 AWG wire is recommended.
See Chapter 4, section Connect Power to Shelves for more information

on power connections.

When connecting the -48 V DC system to power, note the following
precautions:

A 30 amp circuit breaker must be present on the non-grounded DC
circuit conductor, and the installer must ensure that means are
provided for connection of the equipment to the DC source by
permanent wiring methods, and no disconnecting device is located
in the grounded DC circuit conductor between the point of
connection to the supply and the point of connection to the
grounding electrode and equipment grounding conductors.

Run Cables to Base Station Locations

The Base Station locations should be designated on the building floor

plans provided to the field service engineer. Base Stations can be

mounted easily on raised or acoustical ceiling tiles, or on the wall.

Avoid locating Base Stations in high or hard-to-reach places, as this

will hinder maintenance, testing, or repositioning.

Wire specifications

The customer’s wire contractor is responsible for adhering to all
local codes for wiring.