Site Preparation

The following steps must be completed before installing the system

hardware. If the steps are not already completed refer to each

individual section for details.

MCU location prepared. Typically the MCU is installed in the

telephone equipment room. This location must have sufficient

backboard space or rack space, and -48 volt power available.

The correct number of cross-connect blocks (or equivalent) are

installed and connected to a 25-pair Telco wire terminated with an

RJ-21 male connector at the MCU location. The number of blocks

required depends on the number and type of Interface Modules

installed. Refer to Chapter 4, section Prepare Demarc Blocks for

more information.

A two-pair cable to each Base Station as designated on the

building floor plans.

The Base Station wiring is terminated with RJ-45 crimp-on plugs

at the designated Base Station locations. Refer to Chapter 4,

section Terminate Cables at Base Station Locations for more

information.

The Base Station wire is terminated at the appropriate cross-

connect demarc blocks. Refer to Chapter 4, section Connect Cables

from Base Stations and Phone Lines to Demarc Blocks.

The analog or digital phone extensions from the phone system are

terminated at the appropriate cross-connect demarc block and the

block is labeled. Refer to Chapter 4, section Connect Cables from

Base Stations and Phone Lines to Demarc Blocks.

A dedicated dial line is available with an RJ-11 jack for the

diagnostic modem.

An IBM-compatible PC is available to serve as the Operator’s

Console for system administration.

A system administrator is designated for the SpectraLink system.

This person should be present for the installation. The Polycom

field service engineer will provide system training to the system

administrator on the day following the installation.