Site Preparation

PN: 1725-36122-001_N.doc

23

Space for the shelves, which are designed for 19” rack or wall

mounting.

Each shelf measures 15” high x 19” wide x 9” deep, and weighs

approximately 35 pounds fully loaded.

Expansion shelves cannot be located more than 17 cable feet from

the Primary Shelf.

All digital interface modules must be within 250 feet of the

telephone system.

See your telephone system specifications for distance limitations

for analog modules.

Location of the Intershelf Junction Panel (JPI300) adjacent to the

shelves on a multi-shelf system.

The Primary Shelf containing the System Controller (CSC or

CSO306 or 320) must be mounted to allow connection to the

JPI300 with a five-foot cable.

Expansion Shelves (CSC300 or CSO300) must be mounted to allow

connection of the shelf to the JPI300 using 12 feet or less of

cabling.

Space for the -48V power supply connections. Power supply

conduit requires clearance of 1.5” on the rear or side of the

shelves.

Maximum loop length specifications of the telephone system

Maximum wire distance from the MCU to a Base Station (6,000

feet)

Cabling for the Interface Modules and Controller cards. All cables

(except power) are connected to the front face of the cards. Space

is provided to route wiring to the back of the shelf.

Prepare rack or wall

The SpectraLink 6300 MCU can be mounted in a rack or on the wall.

Rack or wall support must be adequate to support the number of

shelves to be installed. Each fully loaded SpectraLink 6300 MCU shelf

weighs approximately 35 pounds.

Rack mounting

Before installing shelves in a rack, be sure the rack is mechanically

fastened to the floor or wall such that it properly supports the number