beautypg.com

Promise Technology VTrak 15110 User Manual

Page 239

background image

Chapter 8: Troubleshooting

231

Connection Lost

Normal result of logging out. Also a result of poor
SCSI/FC cable or network connection.

Disk Notification
Disk Down

Identify the disk drive involved. Power down the
system, remove and test the drive. Replace the drive
as needed.

Disk Plugged In

A disk drive has been plugged into the enclosure.
Normal.

Disk Access Retry

Watch this disk drive. If problems persist, power down
the system, remove and test the drive. Replace the
drive as needed.

Disk CRC Error

Identify the disk drive involved. Power down the
system, remove and test the drive. Replace the drive
as needed.

Disk SMART Failed

Identify the disk drive involved. Power down the
system, remove and test the drive. Replace the drive
as needed.

Disk ECC Error
Disk Bad Sector
Disk Reserve Sector Error
Disk Time Out
Logical Drive
Notification
Create Logical Drive

A new logical drive was created. Normal.

Delete Logical Drive

A logical drive was deleted. Normal.

Logical Drive Critical

If hot-spare is enabled, logical drive will rebuild
automatically with a new disk drive. Identify and
replace the failed drive.
Without a hot spare, the logical drive will attempt to
rebuild the failed drive. If this action repeats, remove
the drive for test and repair or replacement.

Logical Drive Offline

Go to the Promise website and download a document
called Array Recovery Procedures or contact
Technical Support.

Logical Drive Migration
Started

Expansion or RAID level change of logical drive
begun. Normal.

Logical Drive
Notification, cont.

Event

Action